ISO 80369-20 leakage test equipment

ISO 80369-20 Pressure and Positive-Pressure Liquid Leakage Tester

KingPo leakage test equipment for ISO 80369-20 Annex B pressure testing and Annex C positive-pressure liquid leakage workflows.

ISO80369-20 Annex B/C0-600 kPa1 stationCurve display and print report
Direct product answer

This KingPo tester covers ISO 80369-20 Annex B pressure leakage and Annex C positive-pressure liquid leakage workflows. It provides pressure control, sample setup, touch-screen operation, curve display and print report functions for connector leakage test preparation.

Equipment overview

What this equipment does

The equipment page is designed for buyers who need more than a connector photo. It explains what the equipment tests, how the pressure and liquid workflows differ, what the operator sets on the touch screen and what information KingPo needs before quotation.

What the equipment tests

The tester supports Annex B pressure leakage and Annex C positive-pressure liquid leakage for ISO 80369 connector test setups. The test sample, fixture and connector interface determine how the equipment is configured.

Control interface and parameter setting

The owner manual describes touch-screen operation with pressure function selection, test time, test pressure, sample volume, pressure curve display and print report controls.

Liquid leakage setup

For positive-pressure liquid testing, the manual describes connecting the test sample and AIR OUTLET line to the tank valves, filling the funnel until water flows from the sample end, blocking the sample outlet, opening the air valve and starting the test.

Key product information

ModelISO80369-20 Annex B/C leakage tester
KingPo model scopeISO80369-20 Annex B and Annex C
Applicable standardISO 80369-20
Applicable AnnexAnnex B pressure test; Annex C positive-pressure liquid test
Test station1 station
Pressure range0-600 kPa
Accuracy+/- 0.25%
Test time0-9999 s can be set
Power supply220V 50Hz
Report outputCurve display and print test report function
Equipment specifications

Measurement range and equipment functions

The equipment provides pressure testing, positive-pressure liquid workflow support, real-time pressure display, curve display and print report controls. The connector fixture, sample volume and documentation package should be defined before order.

Pressure range0-600 kPa
Accuracy+/- 0.25%
Test time0-9999 s can be set
Test station1 station
Internal pipe volume notesample volume + device pipe volume 1.57 cm3
Named calculation fieldsLeakage rate, lower-limit pressure, starting test pressure, volume to specimen, pressure change and test period
Test functions

Where the equipment fits in the test workflow

ISO 80369-20 Annex B pressure leakage setup
ISO 80369-20 Annex C positive-pressure liquid leakage setup
Connector leakage testing with fixture and sample support
Laboratory report preparation and procurement comparison
Operating workflow

Typical setup and operation flow

  1. Place the device on a stable desktop and connect power.
  2. Turn on the power switch and select the pressure function on the touch screen.
  3. Install the test sample with the required connector and fixture setup.
  4. Set test time, test pressure and sample volume.
  5. Start the test, monitor pressure and curve display, then use print report when required.
  6. For liquid testing, prepare the liquid tank path before starting the pressure liquid test.
Available configurations

Order scope options

  • Annex B pressure leakage configuration
  • Annex C positive-pressure liquid leakage configuration
  • Fixture and connector interface package
  • Report output and documentation package
Documentation

Documents buyers commonly request

  • Datasheet request
  • Operation manual request
  • Report output requirement
  • Fixture and sample setup note
  • Calibration and certificate request
FAQ

Questions buyers ask before ordering

Does one equipment page cover both Annex B and Annex C?

Yes. The KingPo owner manual identifies the scope as ISO80369-20 Annex B and Annex C, covering pressure and positive-pressure liquid workflows.

What information is needed before quotation?

Send the Annex route, connector sample, fixture interface, pressure or liquid requirement, sample volume and report or certificate need.

Does the tester provide report output?

The manual identifies curve display and print report controls. Report wording and certificate requirements should be specified with the RFQ.

Related paths

Continue by buyer question

Send your connector or test setup

Ask KingPo to match the Figure, mating side and test equipment.

Share the standard part, sample photos or drawings, test method, fixture need, quantity and document requirements.

Request this product